VOLTAGE REGULATION
Voltage regulation
description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143
Overvoltage correction
Input voltages between 128 and 143V are reduced by 9%
Undervoltage correction
Input voltages between 97 and 107V are boosted by 10%
Severe undervoltage
correction
Input voltages between 81 and 96V are boosted by 21%
LEDS ALARMS & SWITCHES
LED Indicators
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms
Audible alarm indicates power-failure and low-battery conditions
Alarm cancel operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression joule
rating
510
UPS AC suppression
response time
Instantaneous
EMI / RFI AC noise
suppression
Yes
ISOLATION
Output isolation transformer
Professional grade load isolation transformer
Surge voltage withstand
capability
ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave
Surge voltage attenuation
N-G 2000:1, L-G 240:1, L-N 100:1
Insertion loss
65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500
Khz
PHYSICAL
Installation form factors
supported with included
accessories
Tower
Installation form factors
supported with optional
accessories
Wallmount (UPSWM - tower mounting kit)
Primary form factor
Tower
UPS / Power Module
dimensions in primary form
factor (height x width x
depth / inches)
12.8 x 7.5 x 9.2
UPS / Power Module
dimensions in primary form
factor (height x width x
depth / cm)
32.4 x 19 x 23.5
UPS / Power Module weight
(lbs)
36.4
UPS / Power Module weight
(kg)
16.5