Environmental requirements, Table 9 – Quantum Tape Drive LTO-3 User Manual
Page 58
Chapter 5 Specifications
Environmental Requirements
44
LTO-3 Tape Drive User’s Guide
Environmental Requirements
5
lists the environmental specifications for the LTO-3 Tape Drive.
Table 9
Environmental
Requirements
Average rewind time
(609-m tape)
> 51 seconds
Maximum rewind time
(609-m tape)
< 115 seconds
Average data access time
(609-m tape) from BOW
(beginning of wrap)
58 seconds
Maximum data access time
(609-m tape) from BOW
115 seconds
Average rewind time
(609-m tape)
< 115 seconds
Tape speed
Up to 5.9 meters per second
Specification
Operational
Non-operational
Temperature
+50° to +104°F
(+10° to + 40°C)
–40° to +149°F
(–40° to + 66°C)
Airflow requirements
Internal: 9 CFM (front to back)
N/A
Thermal gradient
11°C per hour (10-40°C)
11°C per hour (10-40°C)
Relative humidity
20% to 80% non-condensing
10% to 95% non-condensing
Specification
Value