beautypg.com

Power supply – Olympus DM-420 User Manual

Page 17

background image

17

1

Po

w

er s

up

ply

Cautions concerning the rechargeable batteries

Read the following descriptions carefully

when you use the Ni-MH rechargeable

batteries.
Discharging:
The rechargeable batteries self-discharge

while this is not in use. Be sure to charge

them regularly before use.
Operating temperature:
The rechargeable batteries are chemical

products. The rechargeable batteries

efficiency may fluctuate even when

operating within the recommended

temperature range. This is an inherent

nature of such products.
Recommended temperature range:
When operating appliance:

0°C - 42°C/ 32°F - 107.6°F

Charging:

5°C - 35°C/ 41°F - 95°F

Storage for a long period:

–20°C - 30°C/ –4°F - 86°F

Using the rechargeable batteries outside

the above temperature range may result in

declining efficiency and shorter battery life.

In order to prevent battery leakage or rust,

remove the rechargeable batteries from the

products when you will not be using them

for a long time, and store them separately.

Notes

• This recorder is designed to fully charge

batteries regardless of their energy level.

However, for best results when charging

newly purchased rechargeable batteries

or batteries that have not been used

for a long time (more than one month),

it is recommended to fully charge the

batteries then discharge repeatedly for 2

to 3 times.

Power supply

• When disposing rechargeable batteries,

always observe the local laws and

regulations. Contact you local recycling

center for proper disposal methods.

• If Ni-MH rechargeable batteries are not

fully discharged, protect against short-

circuiting (e.g. by taping the contacts)

before disposing.