background image

Section 2 - Overview

Page 6

09/11/2008 REV 0.99

AC POWER
INPUT

24 VDC OUTPUT OPTION

SYSTEM GROUND LUG

BATTERY DISCONNECT

ANALOG INPUTS
CHANNELS 7

– 12

(OPTIONAL)

ANALOG INPUTS
CHANNELS 1

– 6

INPUT/OUTPUT

MODULE

(OPTIONAL)

USB TYPE A
(MASTER)

USB TYPE B
(SLAVE)

MEMORY
EXPANSION SLOT

MOUSE/KEYBOARD
CONNECTOR

USB SELECT SWITCH (UNDER)

AUDIO CONNECTOR

SPEED LED

ETHERNET RJ-45

CONNECTOR

ACTIVITY LED

RS-232/RS-485

DB9 CONNECTOR

(OPTIONAL)

AMBIENT

TEMPERATURE

SENSOR

ANALOG INPUT

MODULE

POWER SUPPLY

MODULE

OFF ON

BATTERY BACKUP

2.4 Recorder Rear Panel

The rear panel of the recorder is shown below:

USB SWITCH

2.4.1 Power Supply

The power supply module is at the top of the recorder rear panel. The rear panel of the universal AC version
is shown in above. On the right is the AC power input socket that takes a standard IEC connector. Screw
terminals are available as an option, as is a DC power supply module. To the left is the optional 24 Volt dc
output option which provides isolated voltage to power external sensors (100mA). Below this is the battery
disconnect switch. The battery is used to enable the system to shut down correctly and survive short power
outages or brown outs. It should be disconnected for storage or shipping purposes. The system-grounding
lug is used to properly ground the recorder on installation. NOTE: See

Section 3

for installation and

connection details.

2.4.2 Analog Inputs

The analog input module is available with either 6 or 12 inputs and accepts dc inputs up to +25 volts. These
inputs are isolated from each other and ground and are truly differential. In addition channels 1, 6, 7 and 12

POWER SUPPLY