Oregon Scientific SMARTSYNC WM100 User Manual
Oregon Scientific Health and hygiene
INTRODUCTION
Thank you for selecting this Oregon Scientific
TM
Heart Rate
Logger for your sports and exercise needs. This product allows
you to record your heart rate information from your chest belt and
download it to your PC.
Please keep this manual handy as you use your new product. It
contains practical step-by-step instructions, as well as technical
specifications and warnings you should know.
IMPORTANT The measurement functions built into the WM100
are not meant to substitute professional measurement or
industrial precision devices. Values produced by this unit should
be considered as reasonable representations only.
OVERVIEW
FRONT VIEW
1. LED indicator
2. BUTTON
BACK VIEW
1. Battery compartment
2. Reset hole
3. Belt clip
4. USB cable connection socket
GETTING STARTED
BATTERY
The unit is supplied with a CR2032 cell battery.
The LED indicator will flash red for two seconds before the unit
turns off to indicate the battery is low.
To change the battery:
1. Slide the belt clip off the unit.
2. Use a screwdriver to remove the battery compartment
cover.
3. Replace the battery, matching the polarity (+ / -) as shown.
4. Reattach the battery compartment cover.
RECORDING YOUR EXERCISE SESSION
1. Set up your chest belt.
2. Press BUTTON to power on the unit, and place it next to
your chest belt to enable data reception.
3. Attach the unit to your belt or place it in your pocket. Start
exercising.
4. To end data logging press and hold BUTTON for two
seconds, until the LED flashes amber, then release.
NOTE • The unit has a range of 10cm (4 in) during signal search
and 80 cm (31.5 in) once a signal has been received.
• Before using for the first time
,
please install the software
and connect to your PC to upload time and date
information.
CONNECTING TO CHEST BELT
This product is compatible with heart rate chest belts transmitting
digital or analogue signals on 5.3kHz (such as the chest belts
supplied with the following models: SE102 / SE200 / SE211 /
SE212 / SE232 / SE233). Please check your chest belt user
manual for more information or visit www2.oregonscientific.com
The unit will automatically search for a signal whenever you
power ON the unit. The LED indicator will signal connection
status.
LED SIGNAL
MEANING
GREEN flashes quickly
Searching for signal
GREEN for 3 seconds
Signal found
AMBER for 3 seconds
No signal found
GREEN flashes slowly
Device activated
NOTE If no signal is found after 10 seconds the unit will power
OFF.
SIGNAL RECEPTION
If you change or reset your chest belt during an exercise session,
it may be necessary to search for the signal again.
To force a signal search:
Press and hold BUTTON for 4 seconds and release when unit
is ON.
WARNING Signal interference in the environment due to
electromagnetic disturbances may cause unstable or inaccurate
heart rate readings. These may occur near high voltage power
lines, traffic lights, overhead lines of electric railways, electric bus
lines or trams, televisions, car motors, bike computers, some
motor driven exercise equipment, cellular phones or when you
walk through electric security gates.
LOGGING DATA
Every time the unit receives a signal it starts a new activity record
and begins to store heart rate data. The LED indicator will flash
green every 3 seconds to indicate data is being received.
As soon as the unit stops receiving data or is turned off the
activity record is ended.
To end an activity record / turn unit OFF:
1. Press and hold BUTTON for 2 seconds. The LED will turn
amber.
2. Release BUTTON to turn OFF.
NOTE The unit will automatically deactivate if no heart rate is
detected for 5 minutes, during this time the LED will continue to
flash green. The unit will also deactivate if the battery is low or if
the memory is full.
MEMORY
The data logger can record up to 30 hours at a storage interval of
2 seconds. Up to 99 activity records can be stored.
LED SIGNAL
MEANING
RED flashes slowly
90% of memory full
during exercise
RED steady for 2
Memory full, the unit will
seconds
automatically turn OFF
Memory records can be deleted manually or by using the
SmartSync PC software supplied with this product. To delete
using your PC, please refer to the software Help file.
To manually delete all activity records:
1. Press and hold BUTTON for 4 seconds (when unit is OFF).
The LED will flash amber.
2. Press again to clear memory.
3. The LED will turn green for 1 second to indicate records are
deleted
.
TIP To maximise the product lifetime we recommend waiting until
the memory is nearly full before uploading the data to your PC.
CONNECTING TO YOUR PC
To connect to your PC insert the USB cable into your PC and
attach to the Heart Rate Logger.
RESET
To reset use a thin blunt object to press RESET.
PRECAUTIONS
This product is engineered to give you years of satisfactory
service if you handle it carefully. Here are a few precautions:
• Do not subject the unit to excessive force, shock, dust,
temperature or humidity, which may result in malfunction,
shorter electronic life span, damaged battery and distorted
parts.
• Do not immerse the unit in water. If you spill liquid over it, dry
it immediately with a soft, lint-free cloth.
• Do not clean the unit with abrasive or corrosive materials.
• Do not tamper with the unit’s internal components. Doing
so will invalidate the warranty on the unit and may cause
unnecessary damage. The unit contains no user-serviceable
parts.
• Only use fresh batteries as specified in the user’s instructions.
Do not mix new and old batteries.
• Due to printing limitations, the displays shown in this manual
may differ from the actual display.
• The contents of this manual may not be reproduced without
the permission of the manufacturer.
• Do not dispose this product as unsorted municipal waste.
Collection of such waste separately for special treatment is
necessary.
NOTE The technical specifications for this product and the
contents of the user manual are subject to change without
notice.
SPECIFICATIONS
TYPE
DESCRIPTION
L x W x H
46 x 46 x 17 mm
(1.8 x 1.8 x 0.7 in)
Reception range
10 cm (4 in) signal search
80 cm (31.5 in) signal found
Signal reception
5.3 kHz digital / analogue
Memory
30 hrs (at 2 sec intervals)
99 activity records
Power
1 x CR2032 cell battery.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more
about Oregon Scientific products such as digital cameras; MP3
players; children’s electronic learning products and games;
projection clocks; health and fitness gear; weather stations;
and digital and conference phones. The website also includes
contact information for our Customer Care department in case
you need to reach us, as well as frequently asked questions and
customer downloads.
We hope you will find all the information you need on our website,
however if you’re in the US and would like to contact the Oregon
Scientific Customer Care department directly, please visit:
http://www2.oregonscientific.com/service/default.asp
OR
Call 1-800-853-8883.
For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Universal Wireless
Heart Rate Data Logger (WM100) is in compliance with EMC
directive 89/336/CE. A copy of the signed and dated Declaration
of Conformity is available on request via our Oregon Scientific
Customer Service.
Universal Wireless Heart Rate Data
Logger with PC Download
Model: WM100
USER MANUAL
2
1
1
2
3
4
1
3
2
4
EN
© 2006 Oregon Scientific. All rights reserved.
086L004464-037
WM100_M_USA_OP.indd 1
5/4/06 12:18:51 PM