beautypg.com

Troubleshooting, Troubleshooting symptom probable cause action – Olympus WS 700M User Manual

Page 84

background image

84

7

EN

Troubleshooting

Troubleshooting

Symptom

Probable cause

Action

Recording level too
low

The microphone sensitivity is too low.

Set [Mic Sense] to [High] or [Middle]
(

☞ P.47, P.49).

This could potentially be because
the output level for the connected
external devices are too low.

Adjust the output level for the
connected devices.

Voice files are not
recorded in stereo

The connected external microphone
is monaural.

When recording while an external
monaural microphone is connected,
sound will only be recorded by the
L-channel.

[Rec Mode] is set to a monaural
recording mode.

Set [Rec Mode] to the stereo
recording mode (

☞ P.47, P.49).

[Zoom Mic] is set to the + side.

Set [Zoom Mic] to [Off] (

☞ P.47, P.50).

Cannot find the
recorded Voice File

Wrong folder.

Switch to the correct folder
(

☞ P.22 to P.24).

Noise heard during
playback

The recorder was shaken during
recording.

———

The recorder was placed near a cell
phone or fluorescent lamp while
recording or during playback.

Move the recorder.

Unable to erase the
file

The file is locked.

Unlock the file (

☞ P.47, P.49).

The file is read-only.

Unlock the file or cancel the read-only
setting of the file on the PC.

Unable to erase the
folders

There is a file which cannot be
recognized by the recorder in the
folder.

Connect the recorder to your PC and
erase a folder (

☞ P.67, P.69).

Noise is audible
through the recording
monitor

Acoustic feedback is occurring.

When the built-in speaker amps and
the like are connected there is a risk
that audio feedback will occur while
recording. It is recommended that
you use earphones for the recording
monitor.

Conduct adjustments like separating
the earphones from the microphone
further, do not point the microphone
at the earphones, lower the volume on
the recording monitor, and so on.

Unable to set index
marks, tempmarks

The maximum number of marks has
been reached.

Erase unnecessary marks (

☞ P.35).

The file is locked.

Unlock the file (

☞ P.47, P.49).

The file is read-only.

Unlock the file or cancel the read-only
setting of the file on the PC.

This manual is related to the following products: