When the status indicator is lit/blinks, E-61 – Olympus VP--1 User Manual
Page 61
E-61
When the STATUS Indicator is Lit/Blinks
STATUS indicator
POW
ER
AUTO
MENU
STATUS
POWER
SOURCE
QUICK
MENU
AUDIO
VIDEO
POWER indicator
When the STATUS indicator of the main unit
operation panel is lit or blinks, notification
is being given of the irregularities de-
scribed.
STATUS Indicator
POWER Indicator
Action to Take
STATUS
Blinks red
(0.5 s lit / 0.5 s off)
POWER
Lit red
The temperature has become abnormally high.
*
The thermal protector is activated. If the room tem-
perature is high, move the projector to a cool lo-
cation. If the internal temperature of the projector
is high, check the ventilation holes of the cooling
fan and clean them if they are obstructed.
*
When the thermal protector is activated, the power
is switched off and even if the power is soon
switched back on, the power might not actually
be supplied to the projector. Should this happen,
wait one minute and then switch the power on
again.
If the power still does not come on, wait approxi-
mately 60 minutes until the internal temperature
of the projector drops, then switch on the power
again.
When the aforementioned procedure does not
solve the problem, please contact Olympus Digi-
tal Technical Support.
The lamp will not light up.
Wait one minute or longer while the lamp lighting volt-
age irregularity detection protector is activated and
switch the power on again. If the problem still per-
sists, unplug the power cable and contact Olympus
Digital Technical Support.
STATUS
POWER
Blinks red
(1 s lit / 1 s off)
When the lamp burns out during operation: Blinks amber for 90 seconds and
then is lit amber
When the lamp does not light from the beginning: Lit amber