1.1

Instrument codes

To Order

Model No.

Temperature

Range

Spectral

Response

Target Spot Size

@ Distance **

D/S Optical Ratio

OSP500-(*)

–30 °C to +930 °C

-20°F to +1706°F

8 to 14

µ

m

10mm @ 600mm

0.39 @ 24”

60:1

OSP800-(*)

–30 °C to +930 °C

-20°F to +1610°F

8 to 14

µ

m

10mm @ 600mm

0.39 @ 24”

60:1

OSP1000-(*)

–30 °C to +1000 °C

-20°F to +1830°F

8 to 14

µ

m

10mm @ 1000mm

0.39 @ 39.4”

100:1

OSP1300-(*)

+300 °C to +1300 °C

+570°F to 2370°F

1.6

µ

m

6mm @ 1000mm

0.236 @ 39.4”

167:1

OSP1600-(*)

+600 °C to +1600 °C

+1120°F to 2900°F

1

µ

m

5mm @ 1000mm

0.20 @ 39.4”

200:1

OSP2000-(*)

+600 °C to +2000 °C

+1120°F to +3630°F

1

µ

m

5mm @ 1000mm

0.20 @ 39.4”

200:1

* Insert suffix codes B and C and D from options chart above
** See Target spot size diagram

Note

: all accessories and options must be specified at time of order.

Each Pyrometer supplied with

: Alkaline battery, laser, operators manual, and calibration report

Options
Suffix Code

Description

OSP500

OSP800

OSP1000

OSP1300

OSP1600

OSP2000

-B0

Alkaline battery

std

std

std

std

std

std

-B1

Rechargeable Battery

Opt

Opt

Opt

Opt

Opt

Opt

-C1

Single Laser

Std

No

No

No

No

No

-C2

Twin crossed Lasers

No

Std

Std

Std

Std

Std

-C3

Twin normal Lasers

No

Std

Std

std

Std

Std

-C4

Single Laser with Circle

Std

No

No

No

No

No

-D1

Vinyl Case

Std

Std

No

std

Std

No

-D2

Aluminum Case

Opt

Opt

Std

Opt

Opt

Std

-D3

Memory+Software+RS232 Cable

Opt

Opt

Std

Opt

Opt

Std

-D6

Sighting telescope

No

No

Opt

Opt

Opt

Opt

-D7

Red Point

No

No

No

Opt

Opt

Opt

-D8

Alarms

Std

Std

Std

std

std

Std

-D9

Analog Output

Opt

Std

std

std

std

Std

-DA

Aux Input for Tc K & S

Opt

std

std

std

std

Std

Report of Calibration

std

std

std

std

std

Std

No = Not available

Std = Standard at no extra cost

Single laser

: General application, target center

Single laser with circle

: General application, target center plus target dimension with circle (short distance)

Twin crossed lasers

: General application, target dimension

Twin normal lasers

(parallel): Long distance application over 5m (16’)

Red Point

: High temperature over 1250°C 1x

Sighting Telescope

: High temperature over 1250°C 2x tele

Software

(D3): Includes memory up to 500 values. You can divide them by Tag (20 different). Each value includes

temperature value and date&time (built in real time clock). Tag name with 7 characters on instrument
display. Datalogging manual or automatic with sampling time from 1 to 999 sec. Windows 95 software to
download data to PC and cable. You can view, save, print, export to Excel and graph data.

U.S. and international Patents and Patents Pending.