Installation, Gas connection, Minimum fireplace dimensions – Regency IG35-ULPG User Manual

Page 6: Minimum clearances to combustibles

background image

6

Regency IG35 Gas Inbuilt Fireplace

INSTALLATION

GAS CONNECTION

3) Locate the center point where the fl ue will

pass through the chimney above the appli-
ance. Move the appliance into the exact
location where it is to be installed. Ensure
that the Insert is level.

CAUTION: If the glass is removed for servic-
ing, it must be replaced and closed prior to
operating the appliance.

GAS CONNECTION WARNING:
Only persons licensed to work
with gas piping may make the
necessary gas connections to this
appliance.

1) If the appliance is to be installed into an

existing chimney system or Zero Clearance
Box, thoroughly clean the masonry or factory
built fi replace.

2) The gas connection is 1/2" BSP.

Mantel Clearances

MINIMUM FIREPLACE

DIMENSIONS

The minimum fi replace dimensions for the
Regency gas space heater are shown in the
following diagrams:

Note: A non-combustible mantel may be

installed at a lower height if the fram-
ing is made of metal studs covered
with a non-combustible board.

MINIMUM

CLEARANCES TO

COMBUSTIBLES

The minimum fi replace clearances for the
Regency gas space heater are shown in the
following diagrams:

From Unit:

Sides

A 250 mm

Ceiling

B 1220 mm

Mantel

C see Mantel

Clearances

From Surround (660 mm x 1016 mm):
Sides

D 96 mm

Ceiling

E 1066 mm

Max. Mantle Depth

G 305 mm

Hearth Height

H 0 mm

Hearth Depth

I 300

mm*

Hearth Width

J 1100

mm

Min. Alcove Width

K 1262 mm

Max. Alcove Depth

L 915 mm

* NOTE: No hearth required with screen. Floor
fi nishing material must not be any higher then
the base of the fi replace.

Premium Flush Front Framing

When installing the Premium Flush Front, the
walls surrounding the zero clearance kit must
be made of non-combustible material. See
Diagram below.