beautypg.com

Maintenance, Fan maintenance – Regency IG35-ULPG User Manual

Page 26

background image

26

Regency IG35 Gas Inbuilt Fireplace

MAINTENANCE

FAN MAINTENANCE

To Remove Fan:

1) Turn the unit off and allow it to cool to room temperature,

2) Unplug or disconnect power source to stove.

3) Open the bottom louvre.

4) Remove the ECS harness from the back clip.

5) Remove the 2 screws that secure the fan in place.

6) Pull out the ECS box.

NOTE: The ECS box is held in place with velcro.

7) Carefully slide the fan to the front, rotate it 45 degrees and slide it out

simultaneously with the ECS box.

8) Disconnect all the connectors from the fan and resistor.

9) Remove the fan ground cable.

10) Pull out the fan tray.

11) Remove the 3 screws from the back of the fan tray to remove the

fan.

12) Reverse the above steps to install the new fan.