Vertical Venting
with Two (2) 90° Elbows

Two 45° elbows = One 90° elbow

Option

V

H

V+ V1

Maximum total pipe: length, of
all sections, must not exceed
30 feet.
Total horizontal sections must
not exceed 8 feet.
Minimum of 1 foot between
90° elbows is required.

A)

0’ Min.

2’ Max.

1’ Min.

B)

1’ Min.

4’ Max.

3’ Min.

C)

2’ Min.

5’ Max.

4’ Min.

D)

3’ Min.

6’ Max.

5’ Min.

E)

4’ Min.

7’ Max.

6’ Min.

F)

5’ Min.

8’ Max.

7’ Min.

Vertical Venting
with Three (3) 90° Elbows

Two 45° elbows = One 90° elbow

Option

V

H + H1

V+ V1

Maximum total pipe: length, of
all sections, must not exceed
30 feet.
Total horizontal sections must
not exceed 8 feet.
Minimum of 1 foot between
90° elbows is required.

A)

0’ Min.

2’ Max.

2’ Min.

B)

1’ Min.

2’ Max.

3’ Min.

C)

2’ Min.

3’ Max.

4’ Min.

D)

3’ Min.

4’ Max.

6’ Min.

E)

4’ Min.

5’ Max.

7’ Min.

F)

5’ Min.

6’ Max.

8’ Min.

G)

6’ Min.

7’ Max.

9’ Min.

H)

7’ Min.

8’ Max.

10’ Min.