Gas fireplaces, Vertical venting with two (2) 90° elbows, Vertical venting with three (3) 90° elbows – Regency Zero Clearance Direct Vent Gas Fireplace P36D-NG1 User Manual
Page 5
Vertical Venting
with Two (2) 90° Elbows
Two 45° elbows = One 90° elbow
Option
V
H
V+ V1
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
Total horizontal sections must
not exceed 8 feet.
Minimum of 1 foot between
90° elbows is required.
A)
0’ Min.
2’ Max.
1’ Min.
B)
1’ Min.
4’ Max.
3’ Min.
C)
2’ Min.
5’ Max.
4’ Min.
D)
3’ Min.
6’ Max.
5’ Min.
E)
4’ Min.
7’ Max.
6’ Min.
F)
5’ Min.
8’ Max.
7’ Min.
Vertical Venting
with Three (3) 90° Elbows
Two 45° elbows = One 90° elbow
Option
V
H + H1
V+ V1
Maximum total pipe: length, of
all sections, must not exceed
30 feet.
Total horizontal sections must
not exceed 8 feet.
Minimum of 1 foot between
90° elbows is required.
A)
0’ Min.
2’ Max.
2’ Min.
B)
1’ Min.
2’ Max.
3’ Min.
C)
2’ Min.
3’ Max.
4’ Min.
D)
3’ Min.
4’ Max.
6’ Min.
E)
4’ Min.
5’ Max.
7’ Min.
F)
5’ Min.
6’ Max.
8’ Min.
G)
6’ Min.
7’ Max.
9’ Min.
H)
7’ Min.
8’ Max.
10’ Min.
P36 - P36D Gas Fireplace
39
June 2007 Regency Product Specifi cations Book