Chapter 6. Troubleshooting

When this product does not work properly, check the following.

6.1 Troubleshooting up to Emulator Debugger Startup

Figure 6.1 explains troubleshooting from when power to the emulator is activated until M3T-PD77
starts up (until the Program window opens up). If trouble occurs while the target system is connected,
disconnect the target system and check operation in order to quickly identify the cause.

Figure 6.1 Troubleshooting when the emulator debugger starts up

LED status not normal

LED status normal

Display not normal.
Error has occurred.

Display normal

Display not normal.
Error has occurred.

Display normal

Display normal

(1) or (2)

(1)

(1)

1. Check emulator system connections.
2. Check the oscillator circuit board in the emulation pod is

properly mounted.

3. Download the firmware. (4 and 5 apply only if the target

system is connected.)

4. Check power supply voltage at power supply pins (V

SS

, AV

SS

,

V

CC

and AV

CC

) in the target system.

5. Restart the emulator system. Turn ON power to the emulator

system and target system at the same time.

For remedial action, see "(1) Errors Displayed over the Emem
Dialog Box and Remedial Action" (page 55).

Troubleshooting up to emulator system startup

Emulator system startup normal (end)

(1)

(2)

Front panel LED status at

emulator startup

M3T-PD77 start up 1:

Init dialog box displayed

M3T-PD77 start up 2:

Emem dialog box displayed

M3T-PD77 start up 3:

Program window displayed

1. Check the operating environment of the host machine running

M3T-PD77.

2. It is possible that M3T-PD77 is not properly installed. Reinstall

it.