Rs-232 error codes, Table 6-3 . rs-232 error codes, Pre l iminar y – Runco LIGHTSTYLE LS-HB User Manual
Page 100

84
Runco LS-HB Installation/Operation Manual
PRE
L
IMINAR
Y
RS-232 Error Codes
If an
errcode ? command returns one of the following values, you have encountered a
likely system error requiring the attention of a qualified service technician. Try resetting the 
projector by powering it off, allowing it to cool and powering it on again. Refer to Table 6-3 
and contact your dealer if the problem persists. 
The specific code number identifies the source of the error detected, and is particularly 
useful in cases where the projector is far away. For example, the code “7” means that 
Fan 1 has failed.
status
?
0 = Standby
1 = Powering Up
2 = Displaying
3 = Cooling Down
4 = Error
errcode
?
Refer to RS-232 Error 
Codes, below. 
msgbox
= ?
0 = On
1 = Off
This control enables or 
disables the display of 
power off, source and 
adjustment message 
boxes (brightness, con-
trast etc.). Default value is 
ON.
cal.text1
cal.text2
cal.text3
=
Up to 30 characters.
The LS-HB start-up 
screen is customizable 
with three lines of text of 
up to 30 characters each. 
This text appears below 
the “CALIBRATED FOR:” 
text in the logo screen. 
The allowable characters 
are all numbers, letters 
(uppercase and lower-
case), spaces, and sym-
bols available in the ASCII 
code set.
Table 6-2. Serial Commands (continued)
Operation
Commands
Values
Notes
Table 6-3. RS-232 Error Codes
Error Code
LED Indication
Description
0
Inlet NTC thermal sensor is over temperature.
1
DMD NTC thermal sensor is over temperature.
2
Lamp 1 over temperature.
4
Ballast 1 over temperature.
6
Fan failure upon system power-up.