beautypg.com

Maintenance, Removing valve tray – Regency FIREGENIE FG37-NG User Manual

Page 25

background image

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

25

MAINTENANCE

4) Remove the two outside frame pieces by

removing two screws per side. See dia-

gram below.

REMOVING VALVE TRAY

If your valve requires maintenance or replace-

ment, follow these instructions:

NOTE: Always shut off the gas and dis-

connect the power supply before

removing the valve.

1) Open the front door and carefully remove

the logs and lava rock.

2) Remove the burner by removing the two

1/4" hex head screws. See diagram below.

3) Open the front pedestal door and unhook

chain. You may want to put a soft cloth on

the base of the unit so that when the

pedestal door is open it doesn't scratch the

paint. See diagram below.

5) Remove the front plate by undoing the 6

screws.

6) Disconnect the manual switch cable and

reset cables.

7) Disconnect the gas pipe line at the valve.

8) Remove the pedestal back cover by remov-

ing the 4 Philips screws.

9) Disconnect the 5 pin molex connector.

10) Disconnect the ground wires.

11) Remove the 20 x 1/4" hex head screws

holding the burner tray assembly in place.

12) Carefully lift the burner tray assembly out.

13) To replace the burner tray assembly,

reverse these instructions.

Reset Cables

Ground

Wire

5 Pin

Molex Connector

Manual Switch

Cable

This manual is related to the following products: