FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

Installer Notice:

These instructions must be left with

the appliance.

Minimum pressure: Remove one of the

cables connected to the electric modulator.

Keeping the nut (B) blocked, screw in the

screw (C) to increase the pressure and

screw it out to decrease it. Use a screw-

driver 6 x 1 blade.

NOTE: The outlet pressure must be set to

minimum 0.74 kPa.

After carrying out all adjustments, block

the setting screws with paint, taking care

not to obstruct the breather orifice of the

pressure.

Put back the modulator plastic cap.

WARNING: To ensure the correct opera-

tion of the modulator it is necessary that the

plastic cap (A) is returned to its original

location.

23) At the end of all setting and adjustment

operations, check electrical insulation and

gas leaks.

24) Reverse step 20.

25) Check operation of fan and flame control.

26) Check for proper flame appearance and

glow on logs.

Cable

Electric

Modulator

22) Adjusting the Outlet Pressure

All the adjustments must be carried out

in the following order:

Remove the modulator plastic cap (A) using

needle nose pliers.

Maximum pressure: Turn the unit ON to its

highest input rating. Screw in the nut (B) to

increase the outlet pressure and screw it

out to decrease it. Use a 10 mm wrench.

NOTE: The outlet pressure must be set to

maximum 2.65 kPa.

21) Turn on the gas supply and plug in the

power cord.

C

B

A

INSTALLATION

This manual is related to the following products: