FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

MAINTENANCE

FAN MAINTENANCE

If your fan requires maintenance or replace-

ment it must be performed by an authorised

person. Access to the fan is through the plate

on the rear wall of the firebox. NOTE: the unit

MUST NOT be operated without the fan

access panel securely in place and cor-

rectly sealed.

IMPORTANT: These fans collect a

lot of dust from within your home.

Ensure you maintain these fan mo-

tors on a regular basis by vacuum-

ing out the fan squirrel cages, around

the motor, and around the grills on

the back of the stove.

TO REMOVE FAN

1) Unplug or disconnect power source to

stove.

2) Remove the rear access panel on the back

of the stove. The fan can only be accessed

from the back of the stove.

IMPORTANT

Disconnect power supply

before servicing.

WARNING:

Electrical Grounding Instructions

This appliance is equipped with

a three pronged (grounding) plug

for your protection against shock

hazard and should be plugged

directly into a properly grounded

three-prong receptacle. Do not

cut or remove the grounding

prong from this plug.

3) Unclip the wires from the fan motor.

4) Lift fan off of the 2 pins, tip back and pull

through the opening. Disconnect the green

ground wire from the right side of the fan

as soon as you can reach it.

REPLACING FAN

Reverse the above steps (1 - 4). Make sure the

fan wires and the ground wire are reattached.

Hint for pushing fan down onto pins - rub a bit

of dish soap on the grommet so it will slide

more easily onto the pin. Check to make sure

the fan is seated properly on the pins - try to

move the fan back and forth, there should be

no noise, if there is check that the grommets

haven't come loose.