beautypg.com

Operating instructions, First fire, Lighting instructions – Regency FIREGENIE FG37-NG User Manual

Page 19: Resetting the unit, Shutdown instructions, Fan operation, Adjusting flame height

background image

FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater

19

OPERATING INSTRUCTIONS

FIRST FIRE

The FIRST FIRE in your heater is part of the paint

curing process. To ensure that the paint is

properly cured, it is recommended that you

burn your fireplace for at least four (4) hours

the first time you use it with the fan on.

When first operated, the unit will release an

odour caused by the curing of the paint and the

burning off of any oils remaining from manufac-

turing. Smoke detectors in the house may go off

at this time. Open a few windows to ventilate

the room for a couple of hours. The glass may

require cleaning.

NOTE: The main burner will always start on

"HIGH" and resume it's last setting after

20 seconds of operation.

NOTE: When the glass is cold and the appli-

ance is lit, it may cause condensation

and fog the glass. This condensation is

normal and will disappear in a few

minutes as the glass heats up.

DO NOT ATTEMPT TO CLEAN THE GLASS

WHILE IT IS STILL HOT!

DO NOT BURN THE APPLIANCE WITH-

OUT THE GLASS FRONT IN PLACE.

OPERATING

INSTRUCTIONS

Before operating this appliance, proceed

through the following check list.

1) Read and understand these Instructions

before operating this appliance.

2) Check to see that all wiring is correct and

enclosed to prevent possible shock.

3) Check to ensure there are no gas leaks.

4) Make sure the three pieces of door glass

are properly positioned. Never operate the

appliance with any of the glass removed or

with the door open.

5) Verify that all flueing and the cap is unob-

structed.

6) Verify log placement.

LIGHTING

INSTRUCTIONS

1) Plug the power cord into a power outlet.

2) Press and release the ON/OFF button once

to start the unit.

3) After approximately 3 seconds the spark

ignition system will spark for 40 seconds to

light the main burner.

4) If the main burner does not light, reset the

unit.

RESETTING

THE UNIT

1) Open the pedestal door on the unit.

2) Press the reset button for approximately 3

seconds and release. The reset button is

located on the unit's control panel.

3) Wait for approximately 3 seconds and the

pilot sparks can be heard and seen. It would

take 2 to 3 seconds for the flame to be lit.

SHUTDOWN

INSTRUCTIONS

1) Press the ON/OFF button once.

2) Turn off all electric power to the appliance

if service is to be performed.

FAN OPERATION

Set the fan speed on the control panel located

in behind the pedestal door to adjust fan to the

desired speed.

ADJUSTING FLAME

HEIGHT

There are six flame settings that can be adjust-

ed by pressing and releasing the plus (+) and

minus (-) FLAME button.

The FLAME setting button is located on the

control panel in behind the pedestal door.

Pressing and releasing the plus (+) FAN button

will change the fan speed as follows:

OFF -> LOW -> MEDIUM -> HIGH -> OFF, etc.

Pressing and releasing the minus (-) FAN button

will be the reverse of the above.

Control Panel

This manual is related to the following products: