Setting the heating program

Parameters 08 through 17 refer to ambient tempera-

ture adjustment and boiler operation.

08 Maximum heating temperature

Maximum delivery temperature of boiler in the

heating mode.

09 Minimum heating temperature

Minimum temperature of boiler in the heating

mode. If the outdoor air sensor is not fitted and

parameter 11, internal sensor influence, equals

zero, this parameter is used as a set point for the

temperature of the heating water.

10 Heat adjustment curve for heating water

This is only enabled if an outdoor air sensor is

connected. Relation curve of the outdoor air sen-

sor in the algorithm used to calculate delivery tem-

perature adjustment.

11 Internal sensor influence

Importance of the ambient temperature sensor in

the algorithm used to calculate delivery tempera-

ture adjustment.

12 Not used

13 Ambient sensor offset

Temperature offset of the measured internal sen-

sor; this is used to adapt the value to the place of

installation.

14 Loading default parameters

Set this parameter to 1 to load the default config-

uration of the parameters. The day and time are

not modified.

15 Supplementary heat adjustment constant

Offset parameter in the algorithm used to calculate

delivery temperature adjustment.

16 Software version

This displays the code of the software implement-

ed on the remote control unit.

17 °C/°F selection

This parameter selects whether to view tempera-

tures in °F (Fahrenheit) or °C (Celsius).

WARNING:

Changing the values of parameters

08 through 17 may compromise the normal operation

of the boiler. These parameters should be changed by

qualified technicians only.