Raypak XPAK 120 User Manual
Page 6
Technical level
Setting of parameters 1-17.
Holiday setting
Heating and hot water are disabled. Only the
freeze protection function remains enabled.
After setting the parameters, turn the SELECT knob
back to “RUN.”
Setting the comfort temperature
Turn the left-hand knob (SELECT) to
and turn the EDIT knob to set the required tempera-
ture from 40°F to 104°F (5°C to 40°C). After setting
the parameter, turn the SELECT knob back to “RUN.”
Setting the night setback temperature
Turn the left-hand knob (SELECT) to
and turn the EDIT knob to set the required tempera-
ture from 40°F to 104°F (5°C to 40°C). After setting
the parameter, turn the SELECT knob back to “RUN.”
Setting the domestic hot water temperature
Turn the left-hand knob (SELECT) to and
turn the EDIT knob to set the required temperature
from 95°F to 122°F (35°C to 50°C). After setting the
parameter, turn the SELECT knob back to “RUN.”
Setting the day of the week
Turn the left-hand knob (SELECT) to “1….7” and turn
the EDIT knob to set the required day of the week.
After setting the parameter, turn the SELECT knob
back to “RUN.”
6
“ ”
“ ”
Automatic operation - heating according to
program 2
Heating with program 2. Domestic hot water produc-
tion enabled.
Continual heating in comfort mode (manual)
24-hour heating at comfort temperature. Domestic
hot water production enabled.
Continual heating in setback mode (manual)
24-hour heating at setback temperature. Domestic
hot water production enabled.
Summer mode
No heating (only freeze protection). Domestic hot
water production enabled.
PL
HO
“ ”
RUN MODE
With the left-hand knob (SELECT) turned to “RUN,”
the control panel displays the information required to
check the status of the control panel and boiler. The
information is displayed in Fig. 3 on page 5.
CONTROL PANEL OPERATING MODE
SETTINGS
Turn the left-hand knob (SELECT) to “MODE” and
turn the right-hand knob (EDIT) to set one of the fol-
lowing
operating modes:
Standby / OFF
Heating and hot water are disabled. Only the freeze
protection function remains enabled.
Automatic operation - heating according to
program 1
Heating with program 1. Domestic hot water produc-
tion enabled.