Maintenance and Troubleshooting

Runco VX-40d/-50d/-60d/-80d Owner’s Operating Manual

75

PRE

L

IMINAR

Y

13.Press ENTER to accept the change. This adds the new lamp serial number to the

Lamp History menu and resets the Lamp Hours timer to “0.” Lamp Mode and Lamp
Limit remain as they were for the previous lamp and can be changed at any time.

Figure 5-5. Recording the Serial Number of a New Lamp

Filter Replacement

Whenever you replace the lamp – or more often if the projector is installed in an extremely
dusty environment – you should also replace the two filters located at the front and right
side of the projector.

1. Loosen the six screws holding right side filter access

panel in place. Then, remove the panel.

2. Loosen the two screws holding front filter access

panel in place. Then, remove the panel.

3. Pull the filters out of the projector and discard. Do not

reuse filters.

4. Insert the new filters with the wired side in.

5. Replace the filter access panels and tighten the

screws to secure them.

Always record the serial number of a new lamp. Do this

only if you

have just installed a new lamp. This will ensure that the lamp timer
is not reset on an old lamp and that the number of hours logged on
the lamp is accurate.