Temptracker mod, Cat. i, Cat. iv – Raypak MVB 504 User Manual
Page 7
TempTracker Mod
Raypak’s MVB comes standard with TempTracker Mod. This control can be used for space
heating and hot water supply with eight application-specific modes to meet various appli-
cations, including outdoor reset for heating systems. The control monitors and displays
inlet and outlet temperatures on all applications as well as monitor outdoor temperature
when an outdoor reset mode is selected. Only Raypak’s TempTracker Mod allows for a
user definable outdoor reset slope. Boiler adjustable limits prevent over cycling, saving
energy and extending the life of the boiler. Your MVB is never down with a sensor failure
thanks to Raypak’s exclusive TempTracker software. It can operate with as little as one
functioning sensor, keeping you up and running until service arrives.
•
P or PID logic
•
0-10VDC Setpoint/Direct Drive Input
•
4-20ma output
•
LCD Display
•
Building management direct control
Cat. I*
84%
85%
Cat. I*
84%
Cat. IV
87%
MVB
Input
Recovery Rates (GPH)
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
500
5,091
2,545
1,697
1,273
1,018
848
727
636
566
509
463
424
392
364
339
750
7,636
3,818
2,545
1,909
1,527
1,273
1,091
955
848
764
694
636
587
545
509
1100
11,200
5,600
3,733
2,800
2,240
1,867
1,600
1,400
1,244
1,120
1,018
933
862
800
747
1500
15,273
7,636
5,091
3,818
3,055
2,545
2,182
1,909
1,697
1,527
1,388
1,273
1,175
1,091
1018
1999
20,353 10,177
6,784
5,088
4,071
3,392
2,908
2,544
2,261
2,035
1,850
1,850
1,566
1,454
1,357
MVB
Input
Recovery Rates (GPH)
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
500
5,091
2,545
1,697
1,273
1,018
848
727
636
566
509
463
424
392
364
339
750
7,636
3,818
2,545
1,909
1,527
1,273
1,091
955
848
764
694
636
587
545
509
1045
10,640
5,320
3,547
2,660
2,128
1,773
1,520
1,330
1,182
1,064
967
887
818
760
709
1425
14,682
7,341
4,894
3,670
2,936
2,447
2,097
1,835
1,631
1,468
1,335
1,223
1,129
1,049
979
1900
19,576
9,788
6,525
4,894
3,915
3,263
2,797
2,447
2,175
1,958
1,780
1,631
1,506
1,398
1,305
MVB
Input
Recovery Rates (GPH)
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
500
5,273
2,636
1,758
1,318
1,055
879
753
659
586
527
479
439
406
377
352
750
7,909
3,955
2,636
1,977
1,582
1,318
1,130
989
879
791
719
659
608
565
527
999
10,535
5,267
3,512
2,634
2,107
1,756
1,505
1,317
1,171
1,053
958
878
810
752
702
1250
13,182
6,591
4,394
3,295
2,636
2,197
1,883
1,648
1,465
1,318
1,198
1,098
1,014
942
879
1500
15,818
7,909
5,273
3,955
3,164
2,636
2,260
1,977
1,758
1,582
1,438
1,318
1,217
1,130
1,055
1750
18,455
9,227
6,152
4,614
3,691
3,076
2,636
2,307
2,051
1,845
1,678
1,538
1,420
1,318
1,230
1999
21,080 10,540
7,027
5,270
4,216
3,513
3,011
2,635
2,342
2,108
1,916
1,757
1,622
1,506
1,405
7