beautypg.com

Roberts Gorden DAT100 User Manual

Page 41

background image

SECTION 16: R

EMOVAL

AND

R

EPLACEMENT

P

ARTS

35

SECTION 16: REMOVAL AND REPLACEMENT PARTS

See warnings and notes

on Page 27, Section 13

before removing or replacing parts.

Burner Components
All serviceable burner parts are accessed by the
door on the side of the heater.
See Page 5, Section 4.

16.1 Gas Valve

The VR4605 gas valve is fitted with the V7335A
modureg regulator (P/N L512) supplied as a
separate component.

When replacing the gas valve the modureg will need
to be fitted on site. To fit the modureg, remove the
standard regulator by removing the two screws
retaining the rubber sealing washer.

See Page 35,

Figure 17

Figure 17: Standard Regulator Removal

Fit the modureg ensuring that the rubber seal is in
place and the two screws are tight.

See Page 35,

Section 16.1.1. Once fitted follow commissioning
procedure in

Section 11.

16.1.1 Gas Valve Replacement - (all models)

16.1.2 Gas Valve Replacement continued- (all models)

Replace in reverse order. Verify that the gas flow
direction of the valve is correct. Re-use the "O" ring
seal in the outlet flange where fitted. Check that all
the joints are leak free. Reset gas valve.
See Page 23, Section 11.4.2.

IT IS IMPORTANT THAT ONLY THE CORRECT
GAS VALVES SPECIFIED FOR EACH MODEL

TYPE ARE USED WHEN REPLACING THESE
CONTROLS.

Remove Standard

Regulator

Sealing

Washer

Step 1

Unscrew

gas pipe

from the

valve inlet.

Step 2

Unscrew valve from the

burner manifold

or

unscrew the screws for

the inlet and outlet flanges.

Ignition

Control

Rubber

Seal

Modureg Modulating

Regulator

Description

Part Number

Gas Valve VR4605

90033404

Ignition Control

90434020