Items for Specifying Scan Settings
103
6
D
Specify Original Size (X1 and Y1) using the number keys, and then press
the {q} key.
For example, set X1 to 300 mm and Y1 to 200 mm.
E
Set Start Position (X2 and Y2) to 0 mm, and then press the {q} key.
For example, set X2 and Y2 to 0 mm, and press the {q} key.
F
Specify Scan Area (X3 and Y3) using the number keys, and then press the
{q} key.
For example, set X3 to 300 mm and Y3 to 200 mm.
G
Press [OK].
H
Check Scan Area (X3 and Y3) displayed in the [Custom Size] field, and then
press [OK].
Note
❒ You can specify original sizes (X1 and Y1) of 140 mm or larger.