beautypg.com

Renesas RSKM16C6NK User Manual

Page 13

background image

Table 6-8 below describes the function of the option links associated with Serial configuration. The default configuration is indicated by

BOLD text.

Option Link Settings

Reference

Function

Fitted

Alternative (Removed)

Related To

R14 Programming

Serial Port

Connects SCK to E8a

SCK disconnected from E8a

R12 Programming

Serial Port

Connects E8a to

Programming Serial port.

MUST be removed if R44 fitted. R44

R13 Programming

Serial Port

Connects E8a to

Programming Serial port.

Should be removed if R68 fitted. R68

R44 Programming

Serial Port

Connects RS232 port to

Programming SCI port

MUST be removed if R12, R47

or R49 fitted.

R12, R47, R49

R68 Programming

Serial Port

Connects RS232 port to

Programming SCI port

MUST be removed if R13, R69

or R72 fitted.

R13, R69, R72

R42

RS232 Driver

Enables RS232 Serial

Transceiver

MUST be removed if R39

Fitted

R39

R39 RS232

Driver

Disables RS232 Serial

Transceiver

MUST be removed if R42 Fitted R42

R41

Serial Connector

Connects Alternate serial (CH2)

to D connector

Disconnects Alternate serial

from D connector.

R40

R40

Serial Connector

Connects Alternate serial (CH2)

to D connector

Disconnects Alternate serial

from D connector.

R41

R55

Alternate Serial

Connects Alternate Serial (CH2

- SCIb) to RS232 Transceiver

Should be removed if SCIb

not used for RS232.

R50

R50

Alternate Serial

Connects Alternate Serial (CH2

- SCIb) to RS232 Transceiver

Should be removed if SCIb

not used for RS232.

R55

R72

RS232 Serial on

Application Header

Connects Application Header to

RS232 Transceiver

MUST be removed if R68 or

R69 fitted.

R68, R69

R49

RS232 Serial on

Application Header

Connects Application Header to

RS232 Transceiver

MUST be removed if R44 or

R47 fitted.

R44, R47

R69

RS232 Serial on

SCIa CH0

Connects Serial Channel 0 to

RS232 Transceiver

MUST be removed if R68 or

R72 fitted.

R68, R72

R47

RS232 Serial on

SCIa CH0

Connects Serial Channel 0 to

RS232 Transceiver

MUST be removed if R44 or

R49 fitted.

R44, R49

Table 6-8: Serial Configuration Links