beautypg.com

Section 11 analog control and operation, Mode description, Important notice – RoboteQ Dual Channel Digital Motor Controller AX500 User Manual

Page 93: Section 11, Analog control and operation

background image

AX500 Motor Controller User’s Manual

93

Mode Description

SECTION 11

Analog Control
and Operation

This section describes how the motors may be operated using analog voltage commands.

Mode Description

The AX500 can be configured to use a 0 to 5V analog voltage, typically produced using a
potentiometer, to control each of its two motor channels. The voltage is converted into a
digital value of -127 at 0V, 0 at 2.5V and +127 at 5V. This value, in turn, becomes the com-
mand input used by the controller. This command input is subject to deadband threshold
and exponentiation adjustment. Analog commands can be used to control motors sepa-
rately (one analog input command for each motor) or in mixed mode.

Important Notice

The analog mode can only be used in the Closed Loop speed or position modes
when Optical Encoders are used for feedback. Position potentiometers or tachome-
ters cannot be used since there is only one analog input per channel and since this
this input will be connected to the command potentiometer.