MAINTENANCE SUGGESTIONS

This water heater has been designed and constructed
for a long performance life when installed and operated
properly under normal conditions. Regular inspections,
as outlined in this section, are strongly recommended
as a means of keeping your heater operating efficiently.

1. Cleaning

The water heater must be cleaned annually.
Keep the water heater clear of dust and debris
especially in and around burner.
Cleaning procedures for the Continuum are as
follows:
1) Turn off and disconnect electrical power. Allow

to cool for one hour.

2) Remove the Front Panel by removing screws.

See parts breakdown on panels.

3) Use pressurized air to remove dust from around

main burner.

4) Use soft dry cloth to wipe cabinet.

DO NOT DAMAGE OR DISTORT ANY
PARTS OF HEATER.

DO NOT USE WET CLOTH OR
SPRAY CLEANERS ON BURNER.

2. Visual check of main burner flames.

The burner must flame evenly over the entire sur-
face when operating correctly. The flame must burn
with a clear, blue, stable flame. See the parts
breakdown of the burner for the location of view
ports. Any and all parts removed for inspection or
service must be replaced before operating the unit.
The flame pattern should be as shown in the fol-
lowing Figures.

* VENT MAINTENANCE
* VENT SYSTEM

Must be checked annually for
blockage or deterioration.

* MAINTENANCE-

ELECTRIC MOTORS

Motors are permanently lubri-
cated and need no lubrication.
Keep fan and motor free of
dust and dirt, clean annually.

M A I N T E N A N C E & S E R V I C E I N F O R M AT I O N