beautypg.com

Rinnai CONTINUUM 2424WC User Manual

Page 13

background image

Model 2424WC

800-621-9419

1 3

Code

Displayed

Fault

Remedy

Air Supply or Exhaust Blockage

No Ignition

Flame Failure

Earthing Failure

Remaining Flame Safety Device

Over Temperature Warning

Heat Exchanger Incoming Water

Temperature Sensor Faulty

Outgoing Water Temperature Sensor Faulty

Mod. Solenoid Valve Answer Abnormal

Combustion Fan Failure

Solenoid Valve Driving Circuit Faulty

Flame Sensing Device Faulty

Scale build-up in Heat Exchanger

Check that nothing is blocking
the air intake or exhaust.

Check that the gas is turned
on at the water heater, gas
meter or cylinder.

Check that the gas is turned
on at the water heater and gas
meter. Check for obstructions
in flue outlet.

Service Call

Service Call

Service Call

Service Call

Service Call

Service Call

Service Call

Service Call

10

11

12

14

16

31

32

52

61

71

72

LC

Service Call

E

R

R

O

R

M

E

S

S

A

G

E

S

The Continuum 2424WC has the ability to check its own operation continuously. If a fault oc-
curs, an Error Message will flash on the Digital Monitor of the Remote Controls. This assists
with diagnosing the fault, and may enable you to overcome a problem without a service call.
Please quote the code displayed when inquiring about service.
NOTE: Failure to remedy faults may result in severe burns, scalds, and/or death.