Flue Installation - Concentric Venting (R50LSi, R75LSi, R94LSi)

3 in (75 mm)
minimum

Condensate

Trap

Vertical Termination

(condensate collector must be used in all installations)

3 in (75 mm)
minimum

3 in (75 mm)
minimum

Horizontal Termination using

the Condensate Collector

3 in (75 mm)
minimum

Condensate

Trap

To adjust the condensate collector position or to
replace the female vent top with a male vent top:

1. Loosen the 4 screws at the rear bracket

2. Slide the bracket away from the female vent top.

3. Remove the 4 screws attaching the female vent

top to the water heater.

4. Lift up the female vent top and reposition as

desired (or replace with a male vent top).

5. Install the 4 screws at the vent top and tighten the

4 screws at the bracket.

Secure the first vent component to the water heater
with one self-tapping screw at the hole located above
the condensate collector.

Bracket

Condensate Collector

Securing Screw

Horizontal Termination without using the Condensate Collector

Maximum Height *

5 feet (1.52 m)

Regions of cold climate will create
more condensate in the vent system.
The condensate collector should be
used in cold climates.

If more than one elbow is used in the
vertical section the condensate
collector must be used.

* The condensate collector must be used
in horizontal terminations if a vertical rise
in the vent system exceeds 5ft.

WARNING

If the condensate collector is not used, the drain pipe
must be capped to prevent exhaust gases and
condensate from entering the building. The cap is
supplied on the appliance.