Rinnai REU-VA3237FFU User Manual

Page 18

background image

18

VA Series Indoor LS Manual

to Combustibles

to Non-

Combustibles

R50LSi
R75LSi
R94LSi

R98LSi

Top of
Heater

6 inches
(152 mm)

12 inches
(305 mm)

Back of
Heater

0 (zero) 0

(zero)

Front of
Heater

6 inches
(152 mm)

24 inches
(610 mm)

Sides of
Heater

2 inches
(51 mm)

2 inches
(51 mm)

Floor/
Ground

12 inches
(305 mm)

12 inches
(305 mm)

Vent 0

(zero)

R50LSi
R75LSi
R94LSi

R98LSi

2 inches
(51 mm)

2 inche
(51 mm)

0 (zero) 0

(zero)

6 inches
(152 mm)

24 inche
(610 mm)

1/2 inches
(13 mm)

1/2 inches
(13 mm)

12 inches
(305 mm)

2 inche
(51 mm)

0

4 inches *

(zero)

0 (zero)

Clearances

from

Appliance

Every vent connection must be accessible for inspection, cleaning, and replacement.

The clearance for servicing is 24 inches in front of the water heater

For closet installation: R50LSi, R75LSi, R94LSi: clearance is 6 inches (152 mm) from the front.
R98LSi: clearance is 24 inches (610 mm) from the front.

* 4 inches (102 mm) for enclosed area; 1 inch (26 mm) for unenclosed area.

1. Identify the installation location and confirm that

the installation will meet all required clearances.

2. Securely attach the water heater to the wall using

any of the holes in the wall installation brackets
which are at the top and bottom of the water
heater. Ensure that the attachment strength is
sufficient to support the weight. Refer to the
weight of the water heater in the Specifications
section.

Attachment of the Water Heater

wall installation

brackets

to side

to front

to top

to floor/ground