beautypg.com

Specifications – Rinnai REU-VA3237FFU User Manual

Page 3

background image

VA Series Indoor LS Manual

3

Specifications

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prio

** for commercial and hydronic applications requiring higher temperatures.

r notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.

Model

R50LSi

R75LSi

R94LSi

R98LSi

R98LSi-

ASME

Minimum Gas Consumption Btu/h

15,000

19,000

Maximum Gas Consumption Btu/h

150,000

199,000 Natural Gas

190,000 Propane Gas

237,000

Hot water capacity (Min - Max) *

0.6 - 5.0 GPM

(2.3 - 18.9 L/min)

0.6 - 7.5 GPM

(2.3 - 28.4 L/min)

0.6 - 9.4 GPM

(2.3 - 35.5 L/min)

0.6 - 9.8 GPM

(2.3 - 37 L/min)

Hot water capacity (45ºF rise)

5.0 GPM

(18.9 L/min)

6.6 GPM

(25.0 L/min)

7.4 GPM(28 L/min)

Natural Gas

7.1 GPM(27 L/min)

Propane Gas

8.8 GPM

(33 L/min)

Default Temperature Setting (no controller)

120º F (49º C)

Remote Controller Default Temperature
Setting

104º F (40º C)

Maximum Temp Setting (Commercial **)

160º F (71º C)

185º F (85º C)

Maximum Temp Setting (Residential)

140º F (60º C)

Minimum Temperature Setting

98º F (37º C)

Weight

50 lb (23 kg)

55 lb (25 kg)

Efficiency Rating

Noise level

49 dB

Electrical
Consumption

Normal

53 W

99 W

Standby

2 W

Anti-frost Protection

116 W

By-Pass Control

Fixed

Electronic

Minimum

Gas Supply

Pressure

Natural Gas

5.0 inch W.C.

Propane

8.0 inch W.C.

Maximum

Gas

Supply Pressure

Natural Gas

10.5 inch W.C.

Propane

13.5 inch W.C.

Type of Appliance

Direct Vent, Temperature controlled continuous flow gas hot water system.

Operation

With or without remote controls, mounted in kitchen, bathroom, etc.

Approved Gas Type

Natural Gas or Propane - Ensure unit matches gas type it's being installed on.

Connections

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT

Ignition System

Direct Electronic Ignition

Electric Connections

Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)

Water Temperature Control

Simulation Feedforward and Feedback.

Water Supply Pressure

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)

Maximum Water Supply Pressure

150 PSI

Remote Control Cable

Non-Polarized Two Core Cable (Minimum 22 AWG)

100 W

* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

84.0%

180,000

65 W

79 W