VA Series Indoor LS Manual

WARNING

Turn off the electrical power supply, the manual gas
valve and the manual water control valve whenever
servicing the unit.

Repairs should be performed by a qualified service
technician. The appliance should be inspected
annually by a qualified service technician. Verify
proper operation after servicing.

Cleaning

It is imperative that control compartments, burners,
and circulating air passage ways of the appliance be
kept clean.

Clean as follows:

1. Turn off and disconnect electrical power. Allow to

cool.

2. Remove and clean the water inlet filter.

3. Remove the front panel by removing 4 screws.

4. Use pressurized air to remove dust from the main

burner, heat exchanger, and fan blades. Do not
use a wet cloth or spray cleaners on the burner.
Do not use volatile substances such as benzene
and thinners. They may ignite or fade the paint.

5. Use soft dry cloth to wipe cabinet.

Vent System

The vent system should be inspected at least annually
for blockages or damage.

Motors

Motors are permanently lubricated and do not need
periodic lubrication. Keep fan and motor free of dust
and dirt by cleaning annually.

Remote Controller

Use a soft damp cloth to clean the remote controller.
Do not use solvents.

Lime/Scale Buildup

If you receive Error Code “LC”, refer to the procedure,
Flushing the Heat Exchanger. Refer to the section on
Water Quality to see if your water needs to be treated
or conditioned. (When checking maintenance code
history “00” is substituted for “LC”.)

Visual Inspection of Flame

The burner must flame evenly over the entire surface
when operating correctly. The flame must burn with a
clear, blue, stable flame. See the parts breakdown of
the burner for the location of the view ports.

The flame pattern should be as shown in the figures
below.

Snow Accumulation

Keep the area around flue terminal free of snow and
ice. The appliance will not function properly if the
intake air or exhaust is impeded (blocked or partially
blocked) by obstructions.

Maintenance