Continuous Power Rating (Competition Standard) - Measured at 13.8 Battery Volts

RMS continuous power per channel,

30 Watts x 6

all channels driven into a 4

load

from 20 to 20,000 Hz with less than
0.05% Total Harmonic Distortion (THD)

RMS continuous power per channel,

60 Watts x 6

all channels driven into a 2

load

from 20 to 20,000 Hz, with less than
0.1% Total Harmonic Distortion (THD)

RMS continuous power bridged into a

120 Watts x 3

4

load from 20 to 20,000 Hz, with

less than 0.1% Total Harmonic Distortion (THD)

Dynamic Power Rating (IHF-202 Standard) - Measured at 14.4 Volts
Per channel into a 4

Load

60 Watts x 6

Per channel into a 2

Load

95 Watts x 6

Bridged into a 4

Load

190 Watts x 3

Signal-to-Noise Ratio

> 100dB A-weighted

Frequency Response

20Hz-20kHz

±

0.5dB

Bandwidth

10Hz-250kHz

±

3dB

Damping Factor @ 4

>200 (at output connector)

Slew Rate

30 V/

µ

s

IM Distortion (IHF)

<0.05%

Input Impedance

20k Ohms

Input Sensitivity

Variable from 300mV to 5V
Preset at the factory for 500mV

B+ Fuse Size (External to Amplifier)

50 amp or two 25 amp

Fuse Type

AGU

Crossover Alignment

12dB/octave Butterworth

(XCard C) = 80Hz (.047

µ

f)

(XCard B) = 4.5kHz (.022

µ

f)

(XCard B) = 80Hz (.047

µ

f)

(XCard A) = 80Hz (.047

µ

f)

Dimensions (including end caps)

9

5

8

"H x 18

9

32

"W x 2

5

8

"D

(24.45cm x 46.43cm x 6.67cm)

S