9

MODELS 1287/1336 - 1758/1826

I n l e t / O u t l e t
Header

2-1/2" Inlet

2-1/2" Outlet

1-1/2" Slip Ball Valve

2" Slip
Ball Valve

3" Outlet

Fig. #9270

Fig. #9200

Pump

3" Inlet

2 H.P. Pump

Inlet/Outlet
Header

MODELS 2100-4001

FLOW RATES/WATER CONNECTIONS

MODEL

CONNECTION SIZE

MIN GPM

MAX GPM

926-1223

*

60

120

1287-1826

2-1/2" FPT

Refer to flow rate table

2100-4001

3" FPT

LOOP*

HEATER

FLOW

FLOW

RATES

RATES

MODELS

(GPM)

(GPM)

1287/1336

30-50

85

1414/1468

35-55

85

1571/1631

40-65

85

1758/1826

45-70

85

2100

50-80

180

2500

60-95

180

3001

75-115

180

3500

90-135

180

4001

100-150

180