Raypak 266A User Manual
Page 51
51
CALL
OUT
DESCRIPTION
206A
266A
336A
406A
B
BURNER TRAY
1-B
Burner Tray w/Burners (sea level)*
010391F
010392F
010393F
010394F
Burner Tray w/o Burners (sea level)*
010395F
010396F
010397F
010398F
Burner Tray w/Gas Valve Nat Millivolt
010399F
010400F
010401F
010402F
Burner Tray w/Gas Valve Pro Millivolt
010403F
010404F
010405F
010406F
Burner Tray w/Gas Valve Nat IID
010407F
010408F
010409F
010410F
Burner Tray w/Gas Valve Pro IID
010411F
010412F
010413F
010414F
2-B
Burner Spacer/Hold Down Kit
010415F
010416F
010417F
010418F
3-B
Burner
301210/13
301210/18
301210/22
301210/27
4-B
Burner Orifice Nat. #49 (Sea Level)*
350078F/13 350078F/18 350078F/22 350078F/27
Burner Orifice Pro. #57 (Sea Level)*
350083F/13 350083F/18 350083F/22 350083F/27
5-B
Burner Tray w/o Manifold w/o burners
010421F
010422F
010423F
010424F
C
CONTROLS
1-C
Thermostat Auto Reset 135 Deg Surface Mount
006725F
006725F
006725F
006725F
2-C
AGS 135º (Auto Gas Shut-Off) - Red Epoxy
600892B
600892B
600892B
600892B
3-C
High Limit 140º - Black Epoxy
600893B
600893B
600893B
600893B
4-C
P. C. Board/Control IID Units
010253F
010253F
010253F
010253F
5-C
Thermostat Control MV Units Mechanical
003346F
003346F
003346F
003346F
6-C
Temperature Sensor IID Units
009577F
009577F
009577F
009577F
G
GAS VALVE
1-G
Combination Valve - Nat. MV
003898F
003898F
003898F
003898F
Combination Valve - Pro. MV
003899F
003899F
003899F
003899F
Combination Valve - Nat. IID
003900F
003900F
003900F
003900F
Combination Valve - Pro. IID
004306F
004306F
004306F
004306F
HP
HEAT EXCHANGER - POLYMER
1-HP
Heat Exchange Assy Copper
010043F
010044F
010045F
010046F
Heat Exchange Assy Cupro Nickel
010356F
010357F
010358F
010359F
2-HP
Inlet/Outlet Header Complete
006827F
006827F
006827F
006827F
Inlet/Outlet Header (Includes 6-HP)
006706F
006706F
006706F
006706F
3-HP
Return Header (Includes 6-HP)
006707F
006707F
006707F
006707F
4-HP
Tube Bundle Copper **
010059F
010060F
010061F
010062F
Tube Bundle Cupro Nickel **
010364F
010365F
010366F
010367F
5-HP
Baffle
010038F
005261F
010040F
010041F
6-HP
Flange Nut Kit
008259F
008259F
008259F
008259F
7-HP
O Ring Gasket (2)
006713F
006713F
006713F
006713F
8-HP
Sensor Adapter Digital Electronic
006714F
006714F
006714F
006714F
Sensor Well Millivolt
006805F
006805F
006805F
006805F
9-HP
Bypass Kit
006715F
006715F
006715F
006715F
10-HP
Bypass Valve
006716F
006716F
006716F
006716F
11- HP
Bypass Dam / Shaft
006717F
006717F
006717F
006717F
12-HP
Bypass Spring (All Sizes Included)
006718F
006718F
006718F
006718F
13-HP
Unitherm Governor
006719F
006719F
006719F
006719F
14-HP
Unitherm Governor Plug
006720F
006720F
006720F
006720F
15-HP
Drain Plug
006721F
006721F
006721F
006721F
16-HP
Inlet/Outlet Header Dam
006722F
006722F
006722F
006722F
17-HP
2" PVC Connector & Nut (2)
006723F
006723F
006723F
006723F
18-HP
O Ring (2)
006724F
006724F
006724F
006724F
19-HP
Stainless Steel Baffle
006826F
006826F
006826F
006826F
*FOR INSTALLATION AT OVER 2,000 FEET ABOVE SEA LEVEL, DERATE 4% PER I,000 FEET ABOVE SEA LEVEL.
**WARNING: The Hydraulic conditions or water chemistry that caused the tube bundle to fail have very likely also
damaged the bypass valve and Unitherm Governor. We recommend you replace the Unitherm Governor and
inspect the bypass assembly. Failure to do so could cause premature failure of this replacement part.
ATMOSPHERIC HEATERS