Raypak 266A User Manual
Page 35
35
If the PRS fault code is displayed, it indicates that
there is insufficient water flow through the heater.
Make sure the pool filter and pump strainer are clean
before calling a service representative.
DIAGNOSTICS
The digital thermostat models are equipped with on-
board diagnostic controls. If there is a safety fault, a
fault code will be displayed along with a service
indication.
READING A FAULT
The word “SERVICE” will flash on and off if the PC
board detects a known fault. The fault will be dis-
played in three big letters on the lower left of the dis-
play.
Fig.# 9482
Fig.# 9485
Service Will
Flash
3 Letter
Fault Code
See table
for fault
definition
STATUS CODES
Display
Definition
CFH
Call for heat
CLK
Time clock
EOL
End of line test (Factory Use Only)
LON
Low NOx Unit
LOW
Caution-low water temperature
OFF
Off mode
PRO
Propane gas configured
REM
Remote control activated
SPK
Spark
SPR
Spare fault code indicator
FAULT CODES
Display
Definition
BD1
Board failure
EEP
Microprocessor error
FAN
Blower pressure failure
FFL
Flame sensing when pilot and gas
valves are closed
GVC
Gas valve closed
GVO
Gas valve open
HL1
High limit switch #1 open
HL2
High limit switch #2 open
IGN
Ignition failure
ILO
Ignition lockout
PLT
Pilot failure
PRS
Water pressure switch open
ROL
Heat roll-out safety switch open
SNS
Sensor failure
VNT
Vent switch open
PROGRAM MODES
Display
Definition
CCC
Celsius setting
F/C
Change from Fahrenheit to Celsius
FFF
Fahrenheit setting
RES
Reset defaults
SET
Set point max adjustment
NOTE:
The LCD temperature display may not agree with the temperature reading of your pool or spa ther-
mometer. The heater reads the water temperature at the inlet. Due to the circulation characteristics of any pool
or spa, the water temperature at the inlet to the heater may differ from that observed at a given location in the
pool or spa.