beautypg.com

Raypak 266A User Manual

Page 16

background image

16

SPECIFICATIONS AND DIMENSIONS

Heater

Model

BTUH

Input

(000)

(A)

Cabinet

Width

(B)

Flue

Dia.

(C)

Indoor

Drafthood

(J)

Min.

Gas

Conn.

Water
Conn.

Shipping Weights (lbs)

Standard

Heater

w/Stackless

Top

ASME

Heater

w/Stackless

Top

Indoor

Draft-

hood

R206A

199.5

20”

6”

61-5/8”

11-3/4”

3/4”

2”

187

206

12

R266A

266.0

23”

7”

62”

11”

3/4”

2”

210

229

15

R336A

332.5

26”

8”

63”

10-5/8”

3/4”

2”

230

249

17

R406A

399.0

29”

9”

64-9/16”

12-1/8”

3/4”

2”

249

268

20

ATMOSPHERIC UNITS

Designation for a Digital heater using propane gas is “EP”; a Digital heater using natural gas is “EN”.
Designation for a Millivolt heater using propane gas is “MP”; a Millivolt heater using natural gas is “MN”.
Prefix “C” is for cast iron (ASME) headers; “P” is for plastic (polymer) headers.
Suffix “X” is for cupro-nickel tubing; “C” is for copper tubing.
EXAMPLE: P-R406A-EN-X = Plastic headers, 406 model size, digital, natural gas, cupro-nickel.
Reduce input 4% for each 1000 ft above sea level when installed above 2000 ft elevation.
For Canada, no de-rating is required for elevations up to 4500 ft
Plastic (polymer) headers cannot be used for ASME installations.

B

C

INDOOR

DRAFTHOOD

38"

13-1/4"

GAS

CONNECTION

J

A

26-5/8"

(28-5/8" ASME)

32-11/16"

ELECTRICAL

CONNECTION

40"

STACKLESS

OUTDOOR TOP

28"

4-3/8"

(3-3/8" ASME)

8-7/8"

(6-5/8" ASME)

This manual is related to the following products: