beautypg.com

Gas fireplaces, Warning, Combustible mantels with contemporary faceplate – Regency P33-NG4 User Manual

Page 4: Mantel leg clearances with contemporary faceplate, Clearance requirements with contemporary faceplate

background image

P33 Gas Fireplace

Combustible Mantels with

Contemporary Faceplate

Because of the extreme heat this fi replace emits, the mantel
clearances are critical.
Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed
anywhere in the shaded area or higher.

Mantel Leg Clearances with

Contemporary Faceplate

Combustible mantel leg clearances from side of unit as per diagram
below:
Clearances are from the fi nished edge of the unit or an installed front.

Caution Requirements

The top, back and sides of the fi replace are defi ned by

standoffs. The metal ends of the standoff may NOT be

recessed into combustible construction.

WARNING

Fire hazard is an extreme risk

if these clearances (air space) to combustible materials are not

adhered to. It is of greatest importance that this fi replace and vent

system be installed only in accordance with these instructions.

Clearance:

Dimension

Measured

From:

A: *Front Floor Clearance
(min.)

1" (25mm)

Underside of
Unit

B: *Sidewall

7-1/2" (241mm)

Side of Unit

C: *Ceiling
(room and/or alcove)

30" (889mm)

Top of Unit

D: Alcove Width

48" (1219mm)

Sidewall to
Sidewall
(Minimum)

E: Alcove Depth

36" (914mm)

Front to
Back Wall
(Maximum)

Flue Clearances to

Combustibles

Horizontal - Top

2-1/2"

Horiztonal - Side

1-1/2"

Horiztonal - Bottom

1-1/2"

Vertical (Flex Vent)

1-1/2"

Vertical (Rigid)

1-1/4"

*Note: All measurements are from the top/side

of the unit, not optional front.

Clearance Requirements with

Contemporary Faceplate

Top View

0-3

WARNING

Failure to maintain required clearances is a major cause of chimney related fi res.
Installation of this fi replace must comply with these clearances
Please note:
Due to ongoing product development, product appearance and specifi cations
are subject to change without notice.

C

B

C

Close to Ceiling

31

August 2008 Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

This manual is related to the following products: