beautypg.com

Gas fireplaces, Important – Regency P33-NG4 User Manual

Page 2

background image

Model

P33-NG4 w/

Contemporary

Faceplate

P33-LP4 w/

Contemporary

Faceplate

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (3.00 kPa)

Manifold Pressure - High

3.8” W.C. (0.95 kPa)

11” W.C. (2.74 kPa)

Manifold Pressure - Low

1.1” W.C. (0.27 kPa)

3.3” W.C. (0.82 kPa)

Orifi ce Size

#47 DMS

#56 DMS

Minimum Input
Altitude 0-4500 ft. (0-1372m)

9,800 BTU/h

(2.87 kW)

9,000 BTU/h

(2.64 kW)

Maximum Input
Altitude 0-4500 ft. (0-1372m)

17,500 BTU/h

(5.13 kW)

15,500 BTU/h

(4.54 kW)

Vent Sizing

4” Inner / 6 5/8” Outer

4” Inner / 6 5/8” Outer

P33 Gas Fireplace

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Direct Vent Pro®
American Metal Products® Amerivent Direct
Security Secure Vent®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal

Unit Dimensions

Description

P33 with Contemporary Faceplate

A

Front Face Width

33” (838mm)

B

Rear Firebox Width

23” (584mm)

C

Front Face Height

29” (737mm)

D

Height w/ Standoff

31 1/2” (800mm)

E

Unit Depth

12-3/4” (324mm)

F

Firebox Height

29” (737mm)

Framing Dimensions Description

P33 with Contemporary Faceplate

G

Framing Width

33-1/4” (845mm)

H

**

Framing Height

**

31-3/4” (806mm)

**

I

*

Framing Rise from Floor

1” (25mm) minimum

*

J

Framing
Depth

Vertical

19 1/2” (495mm) Vertical Rise

16 1/2” (419mm) Rigid 12-3/4”

(324mm)

Flex

Horizontal

K

Corner Wall Length

37 1/2” (953mm)

L

Corner Facing Wall Width

53-1/4” (1353mm)

M***

Framed Chase Ceiling***

36” (914mm) Rigid***

32” (813mm) Flex***

N

Vent Centerline Height

30” (762mm) Rigid

26” (660mm) Flex

* The unit must be raised a minimum of 1” above the fi nished fl oor.
** Dimension H = H + I (minimum)
*** Dimension M = M + I (minimum)

Dimension

Description

P33S

O

Gas Connection Height

1 1/2” (38mm)

P

Gas Connection Inset

4” (102mm)

Q

Gas Connection Width

3” (76mm)

R

Minimum Framing Depth

16 1/2” (419mm) Rigid / 12-3/4” (324mm) Flex

S

Maximum Framing Depth
(including wall thickness)

40 1/2” (1028mm) Rigid / 36-3/4” (933mm) Flex

Important:

If the Contemporary Faceplate is used on the P33-NG4/P33-

LP4 Gas Fireplace, the burner orifi ce (Both NG/LP supplied in
package) must be replaced and an overlay decal (also supplied
with kit) must be affi xed to the current serial number decal

supplied with unit.
Note: Also see framing dimensions for this optional front if

installed on the P33-4 unit.


Note:
Unit must be raised up by 1' to allow for faceplate
installation.
NG LP
Current P33-4 orifi ce size: #44 #54
Must replace with: #47 #56

Warning: Fire hazard is an extreme risk if these changes are

not adhered to.

29

August 2008 Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

This manual is related to the following products: