beautypg.com

Gas fireplaces, Vertical termination with co-linear fl ex system – Regency P33-NG4 User Manual

Page 10

background image

Flex Liner

Exhaust

Flue

A maximum

of two certified

joiner kits

may be used

per length.

#948-305

35 ft (11m)

Air Intake

Co-linear DV

Vertical Termination

Cap # 946-529

Co-Linea

Flex

Adapter

with Kit#

946-563

Outer

Pipe

with Kit#

946-563

Inner Pipe

Adapter

with Kit#

946-563

Rigid Pipe Adapter

# 510-994

Pipe Length

45 Elbow

o

Vertical termination with co-linear

fl ex system

The appliance must not be connected to a chimney fl ue
serving a separate solid fuel burning appliance.

Masonry chimneys may take various contours which the fl exible liner
will accommodate. However, keep the fl exible liner as straight as
possible
, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the
termination cap.

This appliance is designed to be attached to two 3” (76mm) co-linear
aluminium fl ex running the full length of the chimney. See the Venting
Arrangements for minimum and maximum heights.

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical Termination Cap

948-305

3” Flex - 35 ft.

946-563

Coaxial to Co-linear Adapter Kit

510-994

Rigid Pipe Adapter

58dva-E45

45º Elbow

Alternate Approved Caps

46dva-VC

Vertical Termination Cap

46dva-VCH

High Wind Cap

46dva-GK

3” Co-linear Adapter with fl ashing

The shaded area in the diagrams show the allowable vertical

terminations.

8'

(2.4m)

Min.

30”

(762mm)

30'

(9.1m)

Max.

30

Horizontal Distance (Feet)

V

ertical

Height

(feet)

2’

(51mm)

max.

Please refer to Exterior Vent Terminations for

additional guidelines on vent locations.

P33 Gas Fireplace

37

August 2008 Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces