F39 Room Sealed Freestanding Gas Stove

9

INSTALLATION

FLUING ARRANGEMENTS

Vertical Terminations Using

Dura-Flue Fluing System for

Residential Manufactured and Mobile Homes

The shaded area in the diagram below shows all allowable combi-
nations of straight vertical and offset to vertical runs with vertical
terminations.
Maximum two 45

o

elbows.

If the fl ue is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4"
clearance to combustibles.

May be installed in Manufactured (Mobile) Homes after fi rst sale.

Horizontal Terminations for All Fluing Systems

The shaded areas in the diagram below show all allowable combina-
tions of vertical runs with horizontal terminations. Maximum one
90

O

elbow (two 45

o

elbows equal one 90

o

elbow).

LPG and NG:

Residential, Manufactured and Mobile

Homes Installations

The fl uing arrangements diagrammed below, have a min. of 75% (fl ue
loss) effi ciency with Fan Off, as required for manufactured homes. (Actual
effi ciency may be as high as 85%)

May be installed in Manufactured (Mobile) Homes after fi rst sale.

Flue Restrictor Position

To set the Flue restriction as indicated in the diagram, simply loosen the
screws and push the fl ue restrictor plate to the correct position. Tighten
the screws.

Flue Restrictor setting at

40 Mj/h

Flue Restrictor setting at

31 Mj/h