5.2.

EDK O

PTIONS

– CJ4

The EDK options provide access to commonly used features of the EDK range.

These jumpers must be fitted at all times to ensure correct operation of the EDK.

Jumper

Function

Setting 1-2

Setting 2-3

CJ 4-A
Default 1-2

Serial Receive
Source

Routes the programming serial
port to the 9Way D Connector

Routes the programming serial port
to the LIN Interface

CJ 4-B
Default 1-2

Serial Transmit
Destination

Routes the programming serial
port to the 9Way D Connector

Routes the programming serial port
to the LIN Interface

CJ 4-C
Default 2-3

Serial Receive
Source

Enable the Flash Programming
header data receive

Enable the RS232 interface data
receive.

CJ 4-D
Default 1-2

BOOT Mode
Selection

User Mode

BOOT Mode

T

ABLE

5-1: B

OARD

O

PTION

: J

UMPER

S

ETTINGS

(D

EFAULT SETTINGS IN BOLD

)

*See section 5.4

The following table lists the connections to each jumper pin.

Pin Net

Name

Description

1

RX232

RS232 received data

2

RX_OPT

Link to below – Data from RS232 or LIN

3 LIN_RX

LIN

received

data

4 TX232

RS232

transmitter

5 PTXD

Data

transmission

6 LIN_TX

LIN

transmitter

7 RX_HDR

Flash

Programming Header received data

8 PRXD

Data

reception

9

RX_OPT

Link to above – Data from RS232 or LIN

10 NC

No

Connection

11

NMIn

NMI used for BOOT mode selection

12 GROUND

System

Ground