beautypg.com

Gas fireplaces – Regency Zero Clearance Direct Vent Gas Fireplace P121/P131-LP2 User Manual

Page 7

background image

Horizontal Venting with Two (2) 90°
Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V

H+ H1

Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 15 feet.
Minimum of 1 foot between
90° elbows is required.

A)

1’ Min.

2’ Max.

B)

2’ Min.

5’ Max.

C)

3’ Min.

8’ Max.

D)

4’ Min.

11’ Max.

E)

5’ Min.

14’ Max.

F)

6’ Min.

15’ Max.

Horizontal Venting with Two (2) 90°
Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H

V

H + H1

Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 12 feet.
Minimum of 1 foot between
90° elbows is required.

A)

1’ Max.

1’ Min.

3’ Max.

B)

3’ Max.

2’ Min.

6’ Max.

C)

5’ Max.

3’ Min.

9’ Max.

D)

8’ Max.

5’ Min.

12’ Max.

Horizontal Venting with Three (3) 90°
Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V+ V1

H + H1

Maximum total pipe: length,
of all sections, must not
exceed 37 feet.
Total horizontal sections
must not exceed 12 feet.
Minimum of 1 foot between
90° elbows is required.

A)

2’ Min.

3’ Max.

B)

3’ Min.

6’ Max.

C)

4’ Min.

9’ Max.

D)

5’ Min.

12’ Max.

Horizontal Venting with Three (3) 90°
Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H

V

H + H1 + H2

Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 12 feet.
Minimum of 1 foot between
90° elbows is required.

A)

1’ Max.

2’ Min.

3’ Max.

B)

3’ Max.

3’ Min.

6’ Max.

C)

5’ Max.

4’ Min.

9’ Max.

F)

7’ Max.

5’ Min.

12’ Max.

P121-P131 Gas Fireplace

75

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

This manual is related to the following products: