Framing and Finishing

1)

Determine the total thickness of facing material (e.g. drywall plus
ceramic tiles) to allow the fi nished surface to be fl ush with the front
of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-¼”
(32mm) thick.

2)

Frame in the enclosure for the unit with framing material.

3)

For exterior walls, insulate the enclosure to the same degree as
the rest of the house, apply vapor barrier and drywall, as per local
installation codes. (Do not insulate the fi replace itself.)

4)

The top of the unit must not be closer than 36” (990mm) to the
ceiling.

5)

Combustible material may be brought up to the top and
sides of the unit and be covered with ceramic tiles, bricks,
rock or other suitable combustible finishing materials.
Note: The unit does not have to be completely enclosed in a
chase. The clearance on top of the unit is 0” to the standoffs
so combustible building materials can be laid directly on top
of the standoffs. You must maintain proper clearances from
the vent to combustible materials (See Below).

6)

Use metal studs for framing where the minimum clearance from
the vent to combustible material cannot be maintained.

Drywall

Mantel Clearances

2

0

12

6

4

8

10

0

Side View

Top of
Unit

12" (305mm)

3 ½" (89mm)

A

Standoff

B

C

Header

3” Extension Trim

Mantel Clearances

A

B

C

Front

36” (914mm)

7” (178mm)

3” (76mm)

P121-P131 Gas Fireplace

Combustible Mantels

Because of the extreme heat this fi replace emits, the mantel
clearances are critical.
Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed
anywhere in the shaded area or higher.

Note: If desired a non-combustible mantel may be installed at a

lower height.

Note: Ensure the paint that is used on the mantel and the facing

is “heat resistant” or the paint may discolour.

Note: If the fi replace is installed
without the 3” Extension Trim,
the facing material must be
non combustible up to 8”
above the unit.

36"min.

(914mm)

36"min.

(914mm)

36"min. (914mm)

Parallel Wall Clearances

Unless otherwise stated the clearances listed below are Minimum
distances to combustible materials. Unit pictured is a P131

Parallel Wall Clearances

P121(LC/RC)/131

Min distance from glass to a parallel wall

36” (914mm)

WARNING

Failure to maintain required clearances is a major cause of
chimney related fi res. Installation of this fi replace must comply
with these clearances.

Clearance:

Dimension

Measured From:

A: Mantel Height

3” (76mm)

Minimum (Additional on this page)

B: Sidewall

0” (0mm)

Side of installed front

3” (76mm)

On P121-2 See-Thru

3” clearance opposite vent.

C: Ceiling

36” (914mm)

Top of installed unit

D: Mantel Depth

12” (305mm)

Maximum (Additional on this page)

E: Alcove Width

See Parallel Wall Clearances.

F: Alcove Depth

36” (914mm)

Front to back wall (Maximum)

Top of Hearth must not be higher than the base of the fi rebox.

Vent Clearances

Clearance Dimension

Horizontal - Top

2-1/2” (64mm)

Horizontal - Side

1-1/2” (38mm)

Horizontal - Bottom

1-1/2” (38mm)

Vertical

1-1/4” (32mm)

E

B

B

A

C

D

F

Clearance Requirements

70

June 2007 Regency Product Specifi cations Book

Gas Fir

eplaces

Gas Fireplaces