Horizontal Venting with One (1) 90°
Elbow

Two 45° elbows = One 90° elbow

Option

V

H

Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 17 feet.
Minimum of 1 foot between
90° elbows is required.

A)

1’ Min.

3’ Max.

B)

2’ Min.

6’ Max.

C)

3’ Min.

9’ Max.

D)

4’ Min.

12’ Max.

E)

5’ Min.

15’ Max.

F)

6’ Min.

17’ Max.

P121-P131 Gas Fireplace

Venting Arrangements - Horizontal

Terminations

This diagram shows allowable venting confi gurations using one 45°.

Note: Must use optional fl ue adapter (Part # 770-994) when using

Rigid Pipe.

Maintain clearances to combustibles.

Horizontal vent must be supported every 3 feet.

Firestops are required at each fl oor level and whenever passing
through a wall.

A vent guard should be used whenever the termination is lower than the
specifi ed minimum or as per local codes.

Note: FPI Direct Vent System (Flex) is only approved for horizontal

terminations.