Instruction Packet

Instruction = WRITE_DATA, Address = 0x18, DATA = 0x01, 0x01


Communication

->[Dynamixel]:FF FF 00 05 03 18 01 01 DD (LEN:009)

<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)

Status Packet Result NO

ERROR

You can verify the Torque Enabled status by trying to move the output of the actuator by

hand.

Example 17

Setting the Compliance Margin to 1 and Compliance Slope to 0x40 for a

Dynamixel actuator with an ID of 0

Compliance

The Angle Error and Torque Output can be represented with the following graph.

CCW

X:Angle Error

CW

Goal Position

CW

CCW

Even if the position deviates a little from the goal position in the CW direction, a large

amount of torque is generated in the CCW direction to compensate for this. However,

since inertia must be considered, a realistic implementation differs from this approach.

Considering this, the given conditions can be represented by the following graph.

CW

Goal Position

Output Torque

Angle(Position)

D

C

A

B

CCW

CW

CCW

A : CCW Compliance Slope (Address0x1D) = 0x40 (about 18.8°)

B : CCW Compliance Margin (Address0x1B) = 0x01 (about 0.29°)

C : CW Compliance Margin (Address0x01A) = 0x01 (about 0.29°)

28