Page 21

background image

DYNAMIXEL

RX-28

Instruction Packet : 0XFF 0XFF 0XFE 0X04 0X03 0X03 0X01 0XF6`

ID LENGTH INSTRUCTION PARAMETERS CHECKSUM

Because it was transmitted with a Broadcast ID (0XFE), no status packets are returned.

4-2. READ_DATA

Function

Read data from the control table of a Dynamixel actuator

Length

0X04

Instruction

0X02

Parameter1

Starting address of the location where the data is to be read

Parameter2

Length of the data to be read

Example 2

Reading the internal temperature of the Dynamixel actuator with an ID of 1

Read 1 byte from address 0x2B of the control table.

Instruction Packet : 0XFF 0XFF 0X01 0X04 0X02 0X2B 0X01 0XCC`

ID LENGTH INSTRUCTION PARAMETERS . CHECKSUM

The returned Status Packet will be as the following.

Status Packet : 0XFF 0XFF 0X01 0X03 0X00 0X20 0XDB

ID LENGTH ERROR PARAMETER1 CHECKSUM

The data read is 0x20. Thus the current internal temperature of the Dynamixel actuator

is approximately 32°C (0X20).