Example, Dynamixel rx-28 – Robotis RX-28 User Manual
Page 26
DYNAMIXEL
RX-28
5. Example
For the following examples, we assume a Dynamixel actuator with an ID of 1 in Reset
status and that the Baud rate is 57142 BPS.
Example 6
Reading the Model Number and Firmware Version of the Dynamixel actuator with
an ID of 1
Instruction Packet
Instruction = READ_DATA, Address = 0x00, Length = 0x03
Communication
->[Dynamixel]:FF FF 01 04 02 00 03 F5 (LEN:008)
<-[Dynamixel]:FF FF 01 05 00 1C 00 08 D5 (LEN:009)
Status Packet Result Model Number = 28 (0x1C) (for the case of RX-28) Firmware Version = 0x08
Example 7
Changing the ID to 0 for a Dynamixel actuator with an ID of 1
Instruction Packet
Instruction = WRITE_DATA, Address = 0x03, DATA = 0x00
Communication
->[Dynamixel]:FF FF 01 04 03 03 00 F4 (LEN:008)
<-[Dynamixel]:FF FF 01 02 00 FC (LEN:006)
Status Packet Result NO
ERROR
Example 8
Changing the Baud Rate of a Dynamixel actuator to 1M bps
Instruction Packet
Instruction = WRITE_DATA, Address = 0x04, DATA = 0x01
Communication
->[Dynamixel]:FF FF 00 04 03 04 01 F3 (LEN:008)
<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)
Status Packet Result NO
ERROR
Example 9
Resetting the Return Delay Time to 4 uSec for a Dynamixel actuator with an ID of
0
A Return Delay Time Value of 1 corresponds to 2uSec.
25