Instruction set and examples, Dynamixel rx-28 – Robotis RX-28 User Manual
Page 20
DYNAMIXEL
RX-28
4. Instruction Set and Examples
The following Instructions are available.
Instruction
Function
Value
Num ber of
Param eter
PING
No action. Used for obtaining a Status Packet
0x01
0
READ DATA
Reading values in the Control Table
0x02
2
W RITE DATA
W riting values to the Control Table
0x03
2 ~
REG W RITE
Sim ilar to W RITE_DATA, but stays in standby
m ode until the ACION instruction is given
0x04
2 ~
ACTIO N
Triggers the action registered by the
REG _W RITE instruction
0x05
0
RESET
Changes the control table values of the
Dynam ixel actuator to the Factory Default Value
settings
0x06
0
SYNC W RITE
Used for controlling m any Dynam ixel actuators
at the sam e tim e
0x83
4~
4-1. WRITE_DATA
Function
To write data into the control table of the Dynamixel actuator
Length
N+3 (N is the number of data to be written)
Instruction
0X03
Parameter1
Starting address of the location where the data is to be written
Parameter2
1st data to be written
Parameter3
2nd data to be written
Parameter N+1
Nth data to be written
Example 1
Setting the ID of a connected Dynamixel actuator to 1
Write 1 to address 3 of the control table. The ID is transmitted using the Broadcasting ID
(0xFE).
19