beautypg.com

Runco DTV-992 User Manual

Page 29

background image

6-7

Random Access Adjustment Mode

Raster Shift Adjustment

The green raster must be centered both horizontally and vertically on the
center of the CRT surface. To center the green raster, look into the green
lens and use the control disc to move the raster.

CAUTION

It is necessary to look into the lenses to perform these adjustments. To
avoid eye discomfort while looking into the lenses, reduce the contrast and
gradually increase the brightness level until the raster becomes visible on
the face of the CRT.

To start the adjustment, use the control disc to highlight Raster shift and
press ENTER to display the green raster on the phosphor.

Press EXIT to return to the Geometry menu.

Note : Horizontal and Vertical shifts for Red and Blue should
end up with a setting close to 50%. If these settings are sig-
nificantly greater or lesser than 50%, contact a RUNCO
authorized service technician.

ENTER will select green raster shift adjustment.
EXIT returns to random access adjustment mode menu.

Warning : In order to ensure maximum CRT longevity and to
avoid CRT damage, do not shift the raster outside the phosphor
area of the CRT.

GEOMETRY

H PHASE

LEFT - RIGHT (E-W)
TOP - BOTTOM (N-S)
SIZE
V LINEARITY
BLANKING

Select with
then
to return.

or

RASTER SHIFT

COARSE SHIFT

GREEN HORIZONTAL
GREEN VERTICAL
RED VERTICAL
BLUE VERTICAL

Select with
then
to return.

or

forbidden area

projected raster

crt faceplate border

phosphor border

correct raster position

wrong raster position