W415-0612 / C / 01.25.08
WIRING DIAGRAM
The main burner and Night Light
TM
switch is located behind
lower access panel. For ease of accessibility, optional re-
mote wall switches may be installed in a convenient location
for both burner and light operation.
The recommended maximum lead length depends on wire
size:
WIRE SIZE
MAX. LENGTH
14
gauge 100
feet
16
gauge
60
feet
18
gauge
40
feet
Route 2-strand (solid core) wire through the electrical hole
located at the bottom left side of the unit. Connect the wires
from the main burner wall switch to the two corresponding
spade connectors on the back of the on/off switch for the
burner located behind the lower access panel. Repeat
connecting the wires to the Night Light
TM
on/off switch for
remote operation.
FIGURE 63
B
ATTERY
H
OLDER
G
AS
V
ALVE
P
ILOT
A
SSEMBLY
I
GNITION
M
ODULE
P
ILOT
G
AS
L
INE
Orange
(I)
[through
independent
conduit]
Yellow
(S)
[through
Gas line
conduit]
AC A
DAPTOR
B
ATTERY
R
ELAY
Red (3 Volt)
Red
Black
W
IRE
H
ARNESS
N
OTE
: W
IRE TAGS
ARE BRACKETED
Brown
(SWI)
Black
(-)
Red
(+)
Green x2
(TH)
Orange x2
(THTP)
Black
Yellow
Blue
Black
(TP)
M
ODULE
P
LUG
R
ELAY
P
LUG
Black
Green
Orange
Black (12 Volt)
*
To Accent Light &
Night Light
TM
Switch
To Optional
Wall Switch
(GD-660)
M
AIN
B
URNER
S
WITCH
*
* See detail for optional
wall switch GD-660 wiring.
Main Burner Switch