beautypg.com

Wiring diagram, See detail for optional wall switch gd-660 wiring – Napoleon Fireplaces Vittoria GD19P User Manual

Page 28

background image

28

W415-0612 / C / 01.25.08

WIRING DIAGRAM

The main burner and Night Light

TM

switch is located behind

lower access panel. For ease of accessibility, optional re-

mote wall switches may be installed in a convenient location

for both burner and light operation.

The recommended maximum lead length depends on wire

size:

WIRE SIZE

MAX. LENGTH

14

gauge 100

feet

16

gauge

60

feet

18

gauge

40

feet

Route 2-strand (solid core) wire through the electrical hole

located at the bottom left side of the unit. Connect the wires

from the main burner wall switch to the two corresponding

spade connectors on the back of the on/off switch for the

burner located behind the lower access panel. Repeat

connecting the wires to the Night Light

TM

on/off switch for

remote operation.

FIGURE 63

B

ATTERY

H

OLDER

G

AS

V

ALVE

P

ILOT

A

SSEMBLY

I

GNITION

M

ODULE

P

ILOT

G

AS

L

INE

Orange
(I)

[through

independent

conduit]

Yellow
(S)

[through
Gas line

conduit]

AC A

DAPTOR

B

ATTERY

R

ELAY

Red (3 Volt)

Red

Black

W

IRE

H

ARNESS

N

OTE

: W

IRE TAGS

ARE BRACKETED

Brown
(SWI)

Black
(-)

Red
(+)

Green x2
(TH)

Orange x2
(THTP)

Black

Yellow

Blue

Black
(TP)

M

ODULE

P

LUG

R

ELAY

P

LUG

Black

Green

Orange

Black (12 Volt)

*

To Accent Light &
Night Light

TM

Switch

To Optional
Wall Switch
(GD-660)

M

AIN

B

URNER

S

WITCH

*

* See detail for optional

wall switch GD-660 wiring.

Main Burner Switch

This manual is related to the following products: